    suspect sticking relays in the fan control box.
    [SIGPIC][/SIGPIC]

  2. #2
    Registered User dobbo's Avatar
    Join Date
    Sep 2009
    Location
    Weston-super-Mare
    Posts
    258

    Default

    Mine does this - when it does I just pull the big 80 amp fuse in the fuse box, and whack it back in when I need to use the car - typically the problem goes away almost immediately when I put the fuse back.

    No idea why but a sticky relay makes sense - I've been meaning to get an auto-electrician to look at it but it needs to be happening at that precise time!

    When this occurs, try putting the AC on for a while, then whack it into ECON mode - this often works for me with the fan turning off a few seconds later.
    Ben Dobson
    X Power Grey 260 SE, #40

    http://www.bendobson.co.uk/blog/

  3. #3
    ZT 400 Keith's Avatar
    Join Date
    Nov 2006
    Location
    Ellesmere, , United Kingdom.
    Posts
    1,898

    Default

    Next time it happens try pulling the connector off the Trinary switch on the AC pipe the one just above the clutch reservoir.
    High pressure in the AC will cause the fan to run but I don't think it should continue with the ignition off.

    Worth trying though as it is a simple test